• DocumentCode
    1378756
  • Title

    Determination of the D.C./A.C. transfer error of an electrostatic voltmeter

  • Author

    Smith, W.E. ; Clothier, W.K.

  • Author_Institution
    Commonwealth Scientific and Industrial Research Organisation (CSIRO), National Standards Laboratory, Division of Electrotechnology, Sydney, Australia
  • Volume
    101
  • Issue
    83
  • fYear
    1954
  • fDate
    10/1/1954 12:00:00 AM
  • Firstpage
    465
  • Lastpage
    469
  • Abstract
    A method for accurately measuring the relative d.c. and a.c. sensitivities of d.c./a.c. transfer instruments is described. The method is applied to an electrostatic voltmeter whose transfer error is found to be less than one part in 10000. In the course of the measurements a sensitive method has been developed for investigating harmonic generation in non-linear filters.
  • Keywords
    transformer insulation; voltmeters;
  • fLanguage
    English
  • Journal_Title
    Proceedings of the IEE - Part II: Power Engineering
  • Publisher
    iet
  • Type

    jour

  • DOI
    10.1049/pi-2.1954.0100
  • Filename