DocumentCode
1378756
Title
Determination of the D.C./A.C. transfer error of an electrostatic voltmeter
Author
Smith, W.E. ; Clothier, W.K.
Author_Institution
Commonwealth Scientific and Industrial Research Organisation (CSIRO), National Standards Laboratory, Division of Electrotechnology, Sydney, Australia
Volume
101
Issue
83
fYear
1954
fDate
10/1/1954 12:00:00 AM
Firstpage
465
Lastpage
469
Abstract
A method for accurately measuring the relative d.c. and a.c. sensitivities of d.c./a.c. transfer instruments is described. The method is applied to an electrostatic voltmeter whose transfer error is found to be less than one part in 10000. In the course of the measurements a sensitive method has been developed for investigating harmonic generation in non-linear filters.
Keywords
transformer insulation; voltmeters;
fLanguage
English