DocumentCode
1379217
Title
Current and power relationships in the measurement of iron losses in a three-limb transformer core
Author
Brailsford, F.
Volume
101
Issue
82
fYear
1954
fDate
8/1/1954 12:00:00 AM
Firstpage
409
Lastpage
416
Abstract
A theoretical investigation of the relative magnitudes of the phase magnetizing currents and of the wattmeter readings when measuring iron losses in a three-core transformer is given. The effect on the accuracy of the observed iron losses of phase-angle errors in the wattmeters is examined. The magnitude of possible errors is shown by numerical example.
Keywords
magnetic leakage; magnetic variables measurement; transformer magnetic circuits;
fLanguage
English
Journal_Title
Proceedings of the IEE - Part II: Power Engineering
Publisher
iet
Type
jour
DOI
10.1049/pi-2.1954.0090