• DocumentCode
    1380546
  • Title

    Rapid determination of corona loss from voltage-charge diagrams

  • Author

    Dixon, H. S.

  • Author_Institution
    Consulting Engineer, Berkeley, Calif.
  • Volume
    78
  • Issue
    2
  • fYear
    1959
  • fDate
    5/1/1959 12:00:00 AM
  • Firstpage
    207
  • Lastpage
    209
  • Abstract
    The measurement of a-c corona loss in laboratory test setups is frequently necessary when the magnitude of the loss is so small that wattmeter instruments cannot be used. An accurate, rapid means using only one measurement from a voltage-charge diagram is presented in this paper.
  • Keywords
    Capacitors; Corona; Loss measurement; Resistors; Sociology; Statistics; Voltage measurement;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Part I: Communication and Electronics, Transactions of the
  • Publisher
    ieee
  • ISSN
    0097-2452
  • Type

    jour

  • DOI
    10.1109/TCE.1959.6372982
  • Filename
    6372982