DocumentCode
1381539
Title
A pulse test set for the measurement of small impedance irregularities in high-frequency cables
Author
Roberts, F.F.
Volume
96
Issue
39
fYear
1949
fDate
1/1/1949 12:00:00 AM
Firstpage
17
Lastpage
23
Abstract
A test set has been developed which enables the degree of impedance irregularity of a high-frequency coaxial cable to be measured in terms of the return loss of echo pulses reflected from the irregularities when short pulses of carrier frequency are fed into the cable. The tester described employs pulses 0.3 microsec long, of a carrier frequency of 20 Mc/s, and can measure echo return losses of up to 90 db.
Keywords
bridge instruments; cables (electric); high-frequency transmission lines;
fLanguage
English
Journal_Title
Proceedings of the IEE - Part III: Radio and Communication Engineering