• DocumentCode
    1381676
  • Title

    Study of AC Losses in a 1-m Long, HTS Power Cable Made From Wide 2G Tapes

  • Author

    Voccio, J. ; Jae-Ho Kim ; Pamidi, S.

  • Volume
    22
  • Issue
    3
  • fYear
    2012
  • fDate
    6/1/2012 12:00:00 AM
  • Firstpage
    5800304
  • Lastpage
    5800304
  • Abstract
    AC loss measurements were carried out on several model power cables fabricated with varying tape width of second generation (2G) high temperature superconductor. The total amount of superconducting tape used in all the cables was kept constant. The results of the measurements show that, contrary to many previous studies, the losses are not proportional to the number of tapes and the width of the gaps between tapes. The purpose of this study is to investigate the losses of a cable using 4 mm, 10 mm and 46-mm wide tapes made by American Superconductor Corporation, helically-wound around a former with minimal gap. Tests were performed in liquid nitrogen. Test results show that the AC losses for these different configurations are similar in magnitude and are in the range of ~25-50 mJ/cycle/m, or ~1.5-3 W/m at 60 Hz near the cable critical current.
  • Keywords
    loss measurement; power cables; superconducting materials; AC loss measurements; American superconductor corporation; HTS power cable; cable critical current; liquid nitrogen; second generation high temperature superconductor; size 10 mm; size 4 mm; size 46 mm; superconducting tape; varying tape; wide 2G tapes; Critical current; High temperature superconductors; Loss measurement; Power cables; Superconducting cables; Superconducting magnets; Testing; AC losses; HTS; cable; wide tape;
  • fLanguage
    English
  • Journal_Title
    Applied Superconductivity, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1051-8223
  • Type

    jour

  • DOI
    10.1109/TASC.2011.2177050
  • Filename
    6086590