• DocumentCode
    1383063
  • Title

    Experiences with a simple titanium ion pump

  • Author

    Pawelko, M. J.

  • Author_Institution
    Amperex Electronic Corporation, Hicksville, N. Y.
  • Volume
    82
  • Issue
    2
  • fYear
    1963
  • fDate
    5/1/1963 12:00:00 AM
  • Firstpage
    277
  • Lastpage
    279
  • Abstract
    The construction, operation, and application of a titanium ion pump, which is a version of the Klopfer-Ermrich getter ion pump, is described. This pump, convenient to use, is of simple, yet rugged construction. Use of the pump in processing vacuum tubes results in savings of time, equipment, space, and operating personnel. Ultimate vacuum level is improved by pumping the tubes during the aging and testing steps which follow the normal exhaust procedure.
  • Keywords
    Anodes; Cathodes; Electron tubes; Gettering; Inductors; Testing; Titanium;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Part I: Communication and Electronics, Transactions of the
  • Publisher
    ieee
  • ISSN
    0097-2452
  • Type

    jour

  • DOI
    10.1109/TCE.1963.6373388
  • Filename