DocumentCode
1385202
Title
Calculation of the difference in impedance for a solenoid coil with and without a sample conductor
Author
Nakane, Hiroshi
Author_Institution
Dept. of Electr. Eng., Sci. Univ. of Tokyo, Japan
Volume
40
Issue
3
fYear
1991
fDate
6/1/1991 12:00:00 AM
Firstpage
544
Lastpage
548
Abstract
Either the resistivity and permeability of a magnetic material or the resistivity and magnetic penetration depth of a superconductor can be simultaneously estimated from the difference in the complex impedance between a circular solenoid coil coaxially surrounding a cylindrical conductor and an identical coil without a sample conductor. A method for calculating the difference in the complex impedance at a high frequency including the displacement current to an accuracy of 0.1% is reported. Comparison of the values calculated by this method and the values obtained by a conventional method which does not include the term of displacement current is also included
Keywords
electrical conductivity measurement; magnetic permeability measurement; penetration depth (superconductivity); solenoids; superconducting materials; circular solenoid coil; complex impedance; cylindrical conductor; displacement current; magnetic material; magnetic penetration depth; permeability; resistivity; sample conductor; superconductor; Coaxial components; Conducting materials; Conductivity; Impedance; Magnetic materials; Permeability; Solenoids; Superconducting coils; Superconducting magnets; Superconducting materials;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/19.87016
Filename
87016