DocumentCode :
1385471
Title :
LROC analysis of detector-response compensation in SPECT
Author :
Gifford, Howard C. ; King, Michael A. ; Wells, R. Glenn ; Hawkins, William G. ; Narayanan, Manoj V. ; Pretorius, P. Hendrik
Author_Institution :
Dept. of Radiol., Massachusetts Univ. Med. Sch., Worcester, MA, USA
Volume :
19
Issue :
5
fYear :
2000
fDate :
5/1/2000 12:00:00 AM
Firstpage :
463
Lastpage :
473
Abstract :
Localization ROC (LROC) observer studies examined whether detector response compensation (DRC) in ordered-subset, expectation-maximization (OSEM) reconstructions helps in the detection and localization of hot tumors. Simulated gallium (Ga-67) images of the thoracic region were used in the study. The projection data modeled the acquisition of attenuated 93- and 185-keV photons with a medium-energy parallel-hole collimator, but scatter was not modeled. Images were reconstructed with five strategies: (1) OSEM with no DRC; (2) OSEM preceded by restoration filtering; (3) OSEM with iterative DRC; (4) OSEM with an ideal DRC; and (5) filtered backprojection (FBP) with no DRC. All strategies included attenuation correction. There were four LROC studies conducted. In a study using a single tumor activity, the ideal DRC offered the best performance, followed by iterative DRC, restoration filtering, OSEM with no DRC, and FBP. Statistical significance at the 5% level was found between all pairs of strategies except for restoration filtering and OSEM with no DRC. A similar ranking was found for a more realistic study using multiple tumor activities. Additional studies considered the effects of OSEM iteration number and tumor activity on the detection improvement that iterative DRC offered with respect to OSEM with no DRC.
Keywords :
image reconstruction; iterative methods; medical image processing; single photon emission computed tomography; tumours; 185 keV; 93 keV; Ga; LROC analysis; SPECT; attenuation correction; detector-response compensation; hot tumors; iterative DRC; localization ROC observer studies; medical diagnostic imaging; medium-energy parallel-hole collimator; multiple tumor activities; nuclear medicine; ordered-subset expectation-maximization reconstructions; simulated gallium images; statistical significance; thoracic region; Attenuation; Detectors; Electromagnetic scattering; Filtering; Image reconstruction; Image restoration; Neoplasms; Optical collimators; Particle scattering; Single photon emission computed tomography; Algorithms; Gallium Radioisotopes; Humans; Image Processing, Computer-Assisted; Lymphoma; Models, Theoretical; Normal Distribution; Observer Variation; Phantoms, Imaging; Poisson Distribution; ROC Curve; Thoracic Neoplasms; Tomography, Emission-Computed, Single-Photon;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/42.870256
Filename :
870256
Link To Document :
بازگشت