DocumentCode :
1386163
Title :
A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography
Author :
Browne, Jolyon ; Pierro, Alvaro R De
Author_Institution :
Adv. Res. & Appl. Corp., Sunnyvale, CA, USA
Volume :
15
Issue :
5
fYear :
1996
fDate :
10/1/1996 12:00:00 AM
Firstpage :
687
Lastpage :
699
Abstract :
The maximum likelihood (ML) approach to estimating the radioactive distribution in the body cross section has become very popular among researchers in emission computed tomography (ECT) since it has been shown to provide very good images compared to those produced with the conventional filtered backprojection (FBP) algorithm. The expectation maximization (EM) algorithm is an often-used iterative approach for maximizing the Poisson likelihood in ECT because of its attractive theoretical and practical properties. Its major disadvantage is that, due to its slow rate of convergence, a large amount of computation is often required to achieve an acceptable image. Here, the authors present a row-action maximum likelihood algorithm (RAMLA) as an alternative to the EM algorithm for maximizing the Poisson likelihood in ECT. The authors deduce the convergence properties of this algorithm and demonstrate by way of computer simulations that the early iterates of RAMLA increase the Poisson likelihood in ECT at an order of magnitude faster that the standard EM algorithm. Specifically, the authors show that, from the point of view of measuring total radionuclide uptake in simulated brain phantoms, iterations 1, 2, 3, and 4 of RAMLA perform at least as well as iterations 45, 60, 70, and 80, respectively, of EM. Moreover, the authors show that iterations 1, 2, 3, and 4 of RAMLA achieve comparable likelihood values as iterations 45, 60, 70, and 80, respectively, of EM. The authors also present a modified version of a recent fast ordered subsets EM (OS-EM) algorithm and show that RAMLA is a special case of this modified OS-EM. Furthermore, the authors show that their modification converges to a ML solution whereas the standard OS-EM does not
Keywords :
algorithm theory; brain; emission tomography; iterative methods; medical image processing; EM algorithm; Poisson likelihood; acceptable image; algorithm convergence properties; body radioactive distribution estimation; emission tomography likelihood maximization; medical diagnostic imaging; nuclear medicine; row-action alternative; row-action maximum likelihood algorithm; Brain modeling; Computational modeling; Computed tomography; Computer simulation; Convergence; Electrical capacitance tomography; Imaging phantoms; Iterative algorithms; Iterative methods; Maximum likelihood estimation;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/42.538946
Filename :
538946
Link To Document :
بازگشت