Abstract :
The MICE spectrometer solenoid magnets will be the first magnets to be installed within the MICE cooling channel. The MICE spectrometer solenoids may be the largest magnets that have been cooled using small two stage coolers. During the previous test of this magnet, the cooler first stage temperatures were too high. The causes of some of the extra first stage heat load has been identified and corrected. The rebuilt magnet had a single stage GM cooler in addition to the three pulse tube coolers. The added cooler reduces the temperature of the top of the HTS leads, the shield and of the first stage of the pulse tube coolers.
Keywords :
magnetic cooling; solenoids; spectrometers; superconducting magnets; GM cooler; MICE cooling channel; MICE spectrometer solenoid magnet; MICE superconducting spectrometer solenoid test; heat load; pulse tube cooler; stage cooler; Coils; Copper; Heating; Lead; Magnetic noise; Magnetic shielding; Superconducting magnets; Pulse tube cooler; solenoid magnet tests;