• DocumentCode
    1387753
  • Title

    The effects of waveform asymmetry on the offtrack capability of an MR head

  • Author

    Feng, Joseph S.

  • Author_Institution
    IBM Storage Syst. Div., San Jose, CA, USA
  • Volume
    32
  • Issue
    5
  • fYear
    1996
  • fDate
    9/1/1996 12:00:00 AM
  • Firstpage
    3872
  • Lastpage
    3874
  • Abstract
    When the waveform distortion in a magnetoresistive head is affected by the alignment between the sensor and the recorded track, changes in the ontrack asymmetry can produce systematic changes in the offtrack capability. A qualitative model is presented to illustrate the mechanism responsible for producing this relationship
  • Keywords
    magnetic heads; magnetic recording noise; magnetoresistive devices; waveform analysis; error rate effects; magnetoresistive head; offtrack capability; ontrack asymmetry; qualitative model; sensor recorded track alignment; shunt biasing; soft film biasing; waveform asymmetry; waveform distortion; Coercive force; Degradation; Error analysis; Magnetic heads; Magnetic sensors; Magnetoresistance; Micromagnetics; Sensor systems; USA Councils; Writing;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.539201
  • Filename