The effects of waveform asymmetry on the offtrack capability of an MR head
Author
Feng, Joseph S.
Author_Institution
IBM Storage Syst. Div., San Jose, CA, USA
Volume
32
Issue
5
fYear
1996
fDate
9/1/1996 12:00:00 AM
Firstpage
3872
Lastpage
3874
Abstract
When the waveform distortion in a magnetoresistive head is affected by the alignment between the sensor and the recorded track, changes in the ontrack asymmetry can produce systematic changes in the offtrack capability. A qualitative model is presented to illustrate the mechanism responsible for producing this relationship
Keywords
magnetic heads; magnetic recording noise; magnetoresistive devices; waveform analysis; error rate effects; magnetoresistive head; offtrack capability; ontrack asymmetry; qualitative model; sensor recorded track alignment; shunt biasing; soft film biasing; waveform asymmetry; waveform distortion; Coercive force; Degradation; Error analysis; Magnetic heads; Magnetic sensors; Magnetoresistance; Micromagnetics; Sensor systems; USA Councils; Writing;