Title :
An electrostatic dust monitor
Author_Institution :
Associated Electrical Industries (Rugby) Ltd., Research Laboratory, Rugby, UK
fDate :
8/1/1960 12:00:00 AM
Abstract :
A smoke or dust particle carried by an air stream and subjected to high-voltage corona acquires a charge approximately proportional to its external surface area. If such ionized particles are precipitated at a collector electrode, the resultant flow of charge constitutes a current proportional to the rate of deposition of total dust surface, and a significant measure of the toxicity of a chimney discharge is obtained. The paper outlines the theory of a dust monitor incorporating this principle, describes some experiments in smoke measurement and examines the operation of prototype equipment in a pulverized-fuelfired boiler installation
Keywords :
boilers; electrostatic precipitators; steam power stations;
Journal_Title :
Proceedings of the IEE - Part A: Power Engineering
DOI :
10.1049/pi-a.1960.0077