DocumentCode :
1387803
Title :
An electrostatic dust monitor
Author :
Grindell, D.H.
Author_Institution :
Associated Electrical Industries (Rugby) Ltd., Research Laboratory, Rugby, UK
Volume :
107
Issue :
34
fYear :
1960
fDate :
8/1/1960 12:00:00 AM
Firstpage :
353
Lastpage :
362
Abstract :
A smoke or dust particle carried by an air stream and subjected to high-voltage corona acquires a charge approximately proportional to its external surface area. If such ionized particles are precipitated at a collector electrode, the resultant flow of charge constitutes a current proportional to the rate of deposition of total dust surface, and a significant measure of the toxicity of a chimney discharge is obtained. The paper outlines the theory of a dust monitor incorporating this principle, describes some experiments in smoke measurement and examines the operation of prototype equipment in a pulverized-fuelfired boiler installation
Keywords :
boilers; electrostatic precipitators; steam power stations;
fLanguage :
English
Journal_Title :
Proceedings of the IEE - Part A: Power Engineering
Publisher :
iet
ISSN :
0369-8882
Type :
jour
DOI :
10.1049/pi-a.1960.0077
Filename :
5242288
Link To Document :
بازگشت