• DocumentCode
    1388100
  • Title

    In vivo measurement of tumor conductiveness with the magnetic bioimpedance method

  • Author

    Smith, Dexter G. ; Potter, Steven R. ; Lee, Benjamin R. ; Ko, Harvey W. ; Drummond, Willie R. ; Telford, Jacqueline K. ; Partin, Alan W.

  • Author_Institution
    Appl. Phys. Lab., Johns Hopkins Univ., Laurel, MD, USA
  • Volume
    47
  • Issue
    10
  • fYear
    2000
  • Firstpage
    1403
  • Lastpage
    1405
  • Abstract
    A noninvasive electromagnetic method has been developed that can effectively measure the in-vivo conductivity difference between rat tumor lines having a low and high metastatic potential. These tumor lines are used in the study of human prostate tumor.
  • Keywords
    biological organs; biomagnetism; biomedical measurement; electrical conductivity measurement; tumours; cancer detection; high metastatic potential; human prostate tumor; in vivo measurement; in-vivo conductivity difference; low metastatic potential; magnetic bioimpedance method; noninvasive electromagnetic method; rat tumor lines; tumor conductiveness; Bioimpedance; Biopsy; Coils; Conductivity measurement; Eddy currents; Electromagnetic measurements; In vivo; Metastasis; Neoplasms; Prostate cancer; Animals; Electric Impedance; Electromagnetics; Humans; Male; Prostatic Neoplasms; Rats; Sensitivity and Specificity; Statistics, Nonparametric; Tumor Cells, Cultured;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/10.871414
  • Filename
    871414