• DocumentCode
    138870
  • Title

    Coil test analysis of Wound-field three-phase flux switching machine with non-overlapping winding and salient rotor

  • Author

    Khan, Faraz ; Sulaiman, Erwan ; Ahmad, Md Zarafi

  • Author_Institution
    Dept. of Electr. Power Eng., Univ. Tun Hussein Onn Malaysia, Parit Raja, Malaysia
  • fYear
    2014
  • fDate
    24-25 March 2014
  • Firstpage
    243
  • Lastpage
    247
  • Abstract
    Topologies for three-phase salient rotor flux-switching machines having DC field winding are presented and coil test analysis, peak armature flux linkage, cogging torque, induced emf and average torque are examined. Salient rotor is used to modulate and switch the polarity of the flux linkage in the armature winding and this is the basic principle of operation of these types of machines. Non-overlapping winding and toothed-rotor are the clear advantages of these topologies as the copper losses gets reduce and rotor becomes more robust. Finite Element Analysis (FEA) is used to examine the three phase topology of proposed Wound-field flux switching motor with non-overlapping winding and salient rotor.
  • Keywords
    coils; finite element analysis; magnetic flux; rotors; torque motors; DC field winding; FEA; armature flux linkage; armature winding; cogging torque; coil test analysis; copper losses; finite element analysis; nonoverlapping winding; three-phase salient rotor; toothed-rotor; wound-field three-phase flux switching machine; Coils; Couplings; Rotors; Stators; Topology; Torque; Windings; Wound-field flux switching motor (WFFSM); non-overlapping winding; salient rotor; topology;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Engineering and Optimization Conference (PEOCO), 2014 IEEE 8th International
  • Conference_Location
    Langkawi
  • Print_ISBN
    978-1-4799-2421-9
  • Type

    conf

  • DOI
    10.1109/PEOCO.2014.6814433
  • Filename
    6814433