DocumentCode
138870
Title
Coil test analysis of Wound-field three-phase flux switching machine with non-overlapping winding and salient rotor
Author
Khan, Faraz ; Sulaiman, Erwan ; Ahmad, Md Zarafi
Author_Institution
Dept. of Electr. Power Eng., Univ. Tun Hussein Onn Malaysia, Parit Raja, Malaysia
fYear
2014
fDate
24-25 March 2014
Firstpage
243
Lastpage
247
Abstract
Topologies for three-phase salient rotor flux-switching machines having DC field winding are presented and coil test analysis, peak armature flux linkage, cogging torque, induced emf and average torque are examined. Salient rotor is used to modulate and switch the polarity of the flux linkage in the armature winding and this is the basic principle of operation of these types of machines. Non-overlapping winding and toothed-rotor are the clear advantages of these topologies as the copper losses gets reduce and rotor becomes more robust. Finite Element Analysis (FEA) is used to examine the three phase topology of proposed Wound-field flux switching motor with non-overlapping winding and salient rotor.
Keywords
coils; finite element analysis; magnetic flux; rotors; torque motors; DC field winding; FEA; armature flux linkage; armature winding; cogging torque; coil test analysis; copper losses; finite element analysis; nonoverlapping winding; three-phase salient rotor; toothed-rotor; wound-field three-phase flux switching machine; Coils; Couplings; Rotors; Stators; Topology; Torque; Windings; Wound-field flux switching motor (WFFSM); non-overlapping winding; salient rotor; topology;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Engineering and Optimization Conference (PEOCO), 2014 IEEE 8th International
Conference_Location
Langkawi
Print_ISBN
978-1-4799-2421-9
Type
conf
DOI
10.1109/PEOCO.2014.6814433
Filename
6814433
Link To Document