• DocumentCode
    1388917
  • Title

    Current Limitation and Power Burden of a Flux-Coupling Type SFCL in the Three-Phase Power System According to Turn´s Ratio and Fault Type

  • Author

    Jung, Byung-Ik ; Choi, Hyo-Sang ; Cho, Yong-Sun ; Chung, Dong-Chul

  • Author_Institution
    Dept. of Electr. Eng., Chosun Univ., Gwangju, South Korea
  • Volume
    21
  • Issue
    3
  • fYear
    2011
  • fDate
    6/1/2011 12:00:00 AM
  • Firstpage
    1225
  • Lastpage
    1228
  • Abstract
    Most of the transmission system has a network structure to improve the reliability and stability of a power system. Fault current is continuously expected to increase by the increase of the power demand. If fault current exceeds the cutoff capacity of a circuit breaker, the circuit breaker is broken and the damage by fault current is expanded throughout the power system. Superconducting fault current limiter (SFCL) was designed to solve this problem in a power system. In this paper, we investigated the current limiting characteristics and power burden of superconducting elements of a flux-coupling type SFCL in three-phase power system. A Flux-coupling type SFCL is one of the resistive type SFCLs. The flux-coupling type SFCL was made by using a transformer. Reactors connected in each phase shared an iron core. When the superconducting elements were quenched in fault phase, the fault current flowed into the primary and secondary coils simultaneously. Thus, the current flowed into primary and secondary coils of sound phase by the magnetic coupling flux. Meanwhile, when the current of sound phase exceeded the critical current of the SFCL, superconducting elements connected in the sound phase were quenched. The value of the fault current tended to decrease as the first reactor´s ratio increased. Furthermore, the power burden of the superconducting element was reduced. The reduced power burden of the superconducting elements shortens the recovery time of the superconducting element, which is advantageous for cooperation with a reclosing system when the SFCL is applied to the system. As a result, we confirmed that the flux-coupling type SFCL operated effectively in the three-phase power system.
  • Keywords
    circuit breakers; magnetic flux; power transmission protection; superconducting fault current limiters; SFCL; circuit breaker; current limitation; fault current; flux coupling; iron core; magnetic coupling flux; superconducting elements; superconducting fault current limiter; three phase power system; transmission system; turn ratio; Circuit breakers; Circuit faults; Fault currents; Inductors; Limiting; Power demand; Critical current; flux-coupling type SFCL; magnetic coupling flux; power burden; reclosing system;
  • fLanguage
    English
  • Journal_Title
    Applied Superconductivity, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1051-8223
  • Type

    jour

  • DOI
    10.1109/TASC.2010.2090438
  • Filename
    5645708