• DocumentCode
    1388919
  • Title

    Fully 3D Bayesian image reconstruction for the ECAT EXACT HR+

  • Author

    Qi, Jinyi ; Leahy, Richard M. ; Hsu, Chinghan ; Farquhar, Thomas H. ; Cherry, Simon R.

  • Author_Institution
    Signal & Image Process. Inst., Univ. of Southern California, Los Angeles, CA, USA
  • Volume
    45
  • Issue
    3
  • fYear
    1998
  • fDate
    6/1/1998 12:00:00 AM
  • Firstpage
    1096
  • Lastpage
    1103
  • Abstract
    A fully 3D Bayesian method is described for high resolution reconstruction of images from the Siemens/CTI ECAT EXACT HR+ whole body positron emission tomography (PET) scanner. To maximize resolution recovery from the system the authors model depth dependent geometric efficiency, intrinsic detector efficiency, photon pair non-colinearity, crystal penetration and inter-crystal scatter. They also explicitly model the effects of axial rebinning and angular mashing on the detection probability or system matrix. By fully exploiting sinogram symmetries and using a factored system matrix and automated indexing schemes, the authors are able to achieve substantial savings in both the storage size and time required to compute forward and backward projections. Reconstruction times are further reduced using multi-threaded programming on a four processor Unix server. Bayesian reconstructions are computed using a Huber prior and a shifted-Poisson likelihood model that accounts for the effects of randoms subtraction and scatter. Reconstructions of phantom data show that the 3D Bayesian method can achieve improved FWHM resolution and contrast recovery ratios at matched background noise levels compared to both the 3D reprojection method and an OSEM method based on the shifted-Poisson model
  • Keywords
    Bayes methods; image reconstruction; image resolution; medical image processing; modelling; positron emission tomography; 3D reprojection method; ECAT EXACT HR+; Huber prior; automated indexing scheme; computation time; contrast recovery ratios; factored system matrix; four processor Unix server; fully 3D Bayesian image reconstruction; high resolution reconstruction; matched background noise levels; multithreaded programming; resolution recovery maximization; shifted-Poisson likelihood model; sinogram symmetries; storage size; whole body PET scanner; Bayesian methods; Detectors; Electromagnetic scattering; Image reconstruction; Image resolution; Particle scattering; Photonic crystals; Positron emission tomography; Solid modeling; Whole-body PET;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.681985
  • Filename
    681985