DocumentCode :
1389116
Title :
Bias magnetic effect using compound magnetic wire sensor in AC magnetic field
Author :
Abe, Susumu ; Ikenaga, Tatsumi ; Suwa, Katsuhito ; Matsushita, Akira
Author_Institution :
Dept. of Electr. Eng., Kanagawa Univ., Yokohama, Japan
Volume :
32
Issue :
5
fYear :
1996
fDate :
9/1/1996 12:00:00 AM
Firstpage :
4971
Lastpage :
4973
Abstract :
A magnetic sensor which consists of a compound magnetic wire and search coil has a novel performance to induce the detection voltage independent of changing rate of AC external field frequency in every one cycle. The detection voltage is changed by the previous magnetized state of the compound magnetic wire. This paper reports the effect of a DC bias magnetic field which is applied with an AC magnetic field to make an asymmetric field. To make a compound wire a previous magnetized state, the demagnetized wire is magnetized by various orienting DC field H0. When a symmetric AC field Hex and DC bias field Hb are applied to the wire, the wire is magnetized by an asymmetric magnetic field, which consists of a reset field Hr=Hex+Hb and a set field Hs=Hex-Hb. According to the relationship among the critical field Hp, H 0 and Hb, Hp is independent of the previous magnetized state of wire at Hb of 25 Oe or larger, and the pulse voltage is always induced at a fixed Hp. This phenomenon is very stable and reproducible
Keywords :
magnetic sensors; AC magnetic field; DC bias magnetic field; asymmetric field; compound magnetic wire sensor; critical field; detection voltage; pulse voltage; search coil; Amorphous magnetic materials; Coils; Magnetic anisotropy; Magnetic cores; Magnetic devices; Magnetic field measurement; Magnetic sensors; Perpendicular magnetic anisotropy; Voltage; Wire;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/20.539305
Filename :
539305
Link To Document :