• DocumentCode
    1389597
  • Title

    Effects of Magnetic Phase on the ECT Signal in the SG Tubes

  • Author

    Park, Duck-Gun ; Ryu, Kwon Sang ; Son, Derac ; Cheong, Yong Moo

  • Author_Institution
    Korea Atomic Energy Res. Inst., Daejeon, South Korea
  • Volume
    46
  • Issue
    2
  • fYear
    2010
  • Firstpage
    560
  • Lastpage
    562
  • Abstract
    The magnetic phase created in the Inconel alloy which is called permeability variation cluster (PVC) results in the distortion of an eddy current test (ECT) signal during the inspection of steam generator (SG) of a nuclear power plant (NPP). The effects of magnetic phase on ECT signals were analyzed using the inspection data of NPP. The hysteresis loops were measured for the PVC which is extracted from retired SG tubes of Kori-1 NPP. The tensile tests were performed to identify the mechanism of PVC creation. The coercivity of PVC is larger than 200 Oe, and hysteresis loop appeared in the tensile tested specimen at 600°C.
  • Keywords
    chromium alloys; coercive force; eddy current testing; iron alloys; magnetic hysteresis; magnetic permeability; nickel alloys; nuclear reactor steam generators; tensile testing; ECT signal; Inconel alloy; coercivity; eddy current test; hysteresis loops; magnetic phase; nuclear power plant; permeability variation cluster; steam generator inspection; temperature 600 degC; tensile tests; Eddy current testing; Eddy currents; Electrical capacitance tomography; Inspection; Magnetic hysteresis; Nuclear power generation; Permeability; Phase distortion; Power generation; Signal generators; Hysteresis loop; magnetic phase; permeability variation cluster (PVC); steam generator (SG) tube;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/TMAG.2009.2034537
  • Filename
    5393119