Title
The detection of incipient breakdown of oil-immersed Bakelized paper contaminated by water
Author
Stannett, A.W.
Volume
109
Issue
3
fYear
1962
fDate
5/15/1905 12:00:00 AM
Firstpage
45
Lastpage
48
Abstract
The insulation-resistance test is used as a non-destructive method of detecting the presence of water in insulating components in service. Water penetrates only the outer layers of oil-immersed Bakelized paper leading to the formation of a low-resistance surface skin. It is shown that, by taking account of the operating conditions, a critical surface conductivity can be estimated above which the insulation will fail in service. The correlation between conductivity under working conditions and insulation resistance is described. A method of estimating a rejection limit of insulation resistance for a component in service is suggested. The measurements needed are stated.