• DocumentCode
    138973
  • Title

    The used of Fast-Fourier Transform (FFT) demodulation for flicker source identification

  • Author

    Jamaludin, Nur Fadhilah ; Abidin, Ahmad Farid

  • Author_Institution
    Fac. of Electr. Eng., Univ. Teknol. MARA Malaysia, Shah Alam, Malaysia
  • fYear
    2014
  • fDate
    24-25 March 2014
  • Firstpage
    537
  • Lastpage
    542
  • Abstract
    Flicker Power Algorithm has been found to be acceptable techniques for flicker source identification in power system. It is due to the scheme of this algorithm that follows the acceptable IEEE Flicker Meter standard. However, these Flicker Power Algorithm techniques are facing the deficiency due the inaccurate flicker power calculation. In this paper, the Flicker Power Algorithm based on Fast Fourier Transform (FFT) demodulation method is proposed to overcome such deficiency. The IEEE 13 bus test system with different location of flicker source has been used to evaluate the effectiveness of the proposed technique.
  • Keywords
    demodulation; fast Fourier transforms; flicker noise; power systems; FFT; IEEE 13 bus test system; IEEE flicker meter standard; demodulation; fast Fourier transform; flicker power algorithm; flicker power calculation; flicker source identification; power system; Demodulation; Equations; Monitoring; Position measurement; Power systems; Voltage fluctuations; Voltage measurement; Electric Arc Furnace; Enhanced Phase-Locked Loop; Flicker Power Algorithm; Phase Detector;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Engineering and Optimization Conference (PEOCO), 2014 IEEE 8th International
  • Conference_Location
    Langkawi
  • Print_ISBN
    978-1-4799-2421-9
  • Type

    conf

  • DOI
    10.1109/PEOCO.2014.6814487
  • Filename
    6814487