• DocumentCode
    1390436
  • Title

    The PHENIX lead-scintillator electromagnetic calorimeter: test beam and construction experience

  • Author

    David, G. ; Goto, Y. ; Kistenev, E. ; Stoll, S. ; White, S. ; Woody, C. ; Bazilevsky, A. ; Belikov, S. ; Chernichenkov, S. ; Denisov, A. ; Kochetkov, V. ; Melnikov, Y. ; Onuchin, V. ; Semenov, V. ; Helikhov, V.S. ; Soldatov, A. ; Usachev, A.

  • Author_Institution
    Brookhaven Nat. Lab., Upton, NY, USA
  • Volume
    45
  • Issue
    3
  • fYear
    1998
  • fDate
    6/1/1998 12:00:00 AM
  • Firstpage
    692
  • Lastpage
    697
  • Abstract
    We have recently completed the production of the 15552 channel lead-scintillator electromagnetic calorimeter for the PHENIX experiment at RHIC. Our design features a single 4 tower module which is repeated throughout and which was produced with a number of quality control steps designed to achieve consistent, large light yields in all channels. We present results on the uniformity of the calorimeter, accuracy of a cosmic muon based precalibration scheme and test beam performance
  • Keywords
    calorimeters; energy loss of particles; solid scintillation detectors; 4 tower module; PHENIX Pb-scintillator electromagnetic calorimeter; Pb; test beam performance; Electromagnetic measurements; Lead; Optical attenuators; Physics; Plasma measurements; Poles and towers; Production; Sampling methods; Structural beams; Testing;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.682617
  • Filename
    682617