DocumentCode
1390440
Title
Protocols and standard crate configuration for a typical CDF Run 2 readout crate
Author
Shaw, Theresa M. ; Stuermer, Walter ; Wesson, Thomas R. ; Wilson, Peter J.
Author_Institution
Fermilab, Batavia, IL, USA
Volume
47
Issue
4
fYear
2000
fDate
8/1/2000 12:00:00 AM
Firstpage
1506
Lastpage
1509
Abstract
This paper describes a standard for the readout and the trigger interface of a VMEbus based crate to be used by the front-end and trigger electronics of the CDF (Colliding Detector Facility) Run 2 experiment. Hereafter, this crate will be referred to as the CDF Readout Crate. The goal is to standardize the implementation of functions that are common among all systems (i.e. power distribution, timing signals, DAQ functions) while allowing some flexibility with other functions (e.g. cooling, rear transition modules, J3 backplanes, etc.). This allows designers of cards that satisfy this standard to have access to a common well defined crate system with interfaces to the trigger and DAQ system, allowing them to concentrate their efforts on the functions they need. This paper lists the mechanical specifications, readout scheme, backplane and signal distribution specifications of the CDF Readout Crate. The paper will also go into some detail on the TRigger And Clock+Event Readout (TRACER) module, a common CDF crate module which provides the crate interface to the system clock and the trigger system
Keywords
high energy physics instrumentation computing; protocols; system buses; CDF; CDF Readout Crate; Run 2 experiment; TRACER module; VMEbus based crate; backplane; protocols; readout scheme; signal distribution; Backplanes; Bandwidth; Clocks; Connectors; Data acquisition; Detectors; Pins; Power distribution; Protocols; Rabbits;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/23.873006
Filename
873006
Link To Document