• DocumentCode
    139072
  • Title

    A setup for the assessment of the effect of tubular confinement on the acoustic response of microbubbles

  • Author

    Butler, Mairead B. ; Dermitzakis, Aris ; Looney, Padraig ; Thomas, David H. ; Pye, Stephen D. ; Sboros, Vassilis

  • Author_Institution
    Univ. of Edinburgh, Edinburgh, UK
  • fYear
    2014
  • fDate
    26-30 Aug. 2014
  • Firstpage
    242
  • Lastpage
    245
  • Abstract
    Ultrasound contrast agents are gas filled microbubbles which produced enhanced echoes in ultrasound imaging thus allowing the acquisition of detailed information on the path of blood. It is theoretically known that the size of a vessel affects the behavior of a microbubble, which could potentially be used to discriminate different sized vessels. This information would be useful in the monitoring of neovascularization in tumor growth or treatment. However, currently it is not possible to identify the vessel diameter by any means of signal processing of microbubble echoes. In order to assess microbubble behavior when confined in tubes we compared the acoustic backscatter from biSphere™ microbubbles both free in water and flowing in 200 μm diameter tubes that are similar in size to arterioles. Experimental systems that allow the interrogation of individual microbubbles were designed and modified to allow investigation of both free microbubbles and those in tubes. Unprocessed single microbubble RF data were collected, allowing the calculation of both the fundamental and second harmonic components of the backscattered signal. Microbubbles confined in tubes had lower amplitude response compared to unconfined microbubbles. On consecutive insonations of the same microbubble, free microbubbles produced echoes above noise more often than confined microbubbles. This setup may be used to investigate microbubble behavior in a range of smaller tubes with diameters similar to capillaries thus enabling signal processing design for vessel differentiation.
  • Keywords
    biomedical ultrasonics; blood flow measurement; blood vessels; bubbles; medical image processing; tumours; acoustic backscatter; acoustic response; arterioles; backscattered signal; biSphere microbubbles; blood path; capillaries; consecutive insonations; free microbubbles; fundamental harmonic components; gas filled microbubbles; information acquisition; microbubble behavior; microbubble echoes; neovascularization monitoring; second harmonic components; signal processing design; size 200 mum; treatment; tubular confinement assessment; tumor growth; ultrasound contrast agents; ultrasound imaging; unconfined microbubbles; unprocessed single microbubble RF data; vessel diameter; vessel differentiation; vessel size; water; Acoustics; Biomedical imaging; Electron tubes; Harmonic analysis; Oscillators; Ultrasonic imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2014 36th Annual International Conference of the IEEE
  • Conference_Location
    Chicago, IL
  • ISSN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/EMBC.2014.6943574
  • Filename
    6943574