DocumentCode :
1391703
Title :
Absolute calibration of a standard temperature noise source for use with s-band radiometers
Author :
Hughes, V.A.
Volume :
103
Issue :
11
fYear :
1956
fDate :
9/1/1956 12:00:00 AM
Firstpage :
669
Lastpage :
672
Abstract :
To provide a standard temperature noise source for use with S-band radiometers, the noise power from the argon discharge tube CV1881 has been calibrated at 2860 Mc/s using radiometer techniques. The absolute value of the effective temperature of the tube with a discharge current of 180 mA, when mounted across a waveguide parallel to the E-plane and properly matched, is 11 140° K (15.73 dB) with a maximum error of 260° K (0.10 dB), and represents a considerable improvement in accuracy over previous measurements. Since this tube shows a high degree of stability and consistency, it is suggested that it could be used as an absolute standard noise source for the measurement of the noise factor of receivers.
Keywords :
microwave measurement;
fLanguage :
English
Journal_Title :
Proceedings of the IEE - Part B: Radio and Electronic Engineering
Publisher :
iet
Type :
jour
DOI :
10.1049/pi-b-1.1956.0230
Filename :
5243007
Link To Document :
بازگشت