DocumentCode
1392503
Title
Surface Flashover of Cylindrical G10 Under ac and dc Voltages at Room and Cryogenic Temperatures
Author
Rodrigo, Horatio ; Baumgartinger, Wolfgang ; Heller, George H. ; Crook, Danny G. ; Ranner, Steven L.
Author_Institution
Center for Adv. Power Syst., Florida State Univ., Tallahassee, FL, USA
Volume
21
Issue
3
fYear
2011
fDate
6/1/2011 12:00:00 AM
Firstpage
1409
Lastpage
1412
Abstract
The results of experimental determination of surface flashover breakdown voltage under high voltage ac and dc for cylindrical G10 are presented. The results are analysed using Weibull statistics and are compared with theoretical field calculations obtained using Ansoft, which is a software package based on finite element analysis. The results show that there is significant improvement of the parameters such as surface flashover voltage and reliability of the results at 77 k over those at 293 K.
Keywords
Weibull distribution; cryogenics; flashover; glass fibre reinforced plastics; reliability; SiO2; Weibull statistics; cryogenic temperatures; cylindrical G10; finite element analysis; reliability; surface flashover breakdown voltage; temperature 293 K to 298 K; temperature 77 K; Breakdown voltage; Dielectrics; Electric breakdown; Electrodes; Insulators; Nitrogen; Temperature measurement; Cryogenics; dielectrics; surface flashover;
fLanguage
English
Journal_Title
Applied Superconductivity, IEEE Transactions on
Publisher
ieee
ISSN
1051-8223
Type
jour
DOI
10.1109/TASC.2010.2089959
Filename
5654568
Link To Document