DocumentCode
1394949
Title
Evaluation of three different optical fibre temperature sensor types for application in gamma radiation environments
Author
Berghmans, Francis ; Decreton, M.
Author_Institution
Belgian Nucl. Res. Centre, Mol
Volume
45
Issue
3
fYear
1998
fDate
6/1/1998 12:00:00 AM
Firstpage
1537
Lastpage
1542
Abstract
We compare the gamma radiation response of three different types of commercially available optical fibre temperature sensors. These are semiconductor absorption, Fabry-Perot cavity and fluorescence sensors. In order to evaluate their possible application in nuclear environments, we first highlight the principles of operation and the constructions. We then report on the gamma irradiation results and explain the observed degradation phenomena. For all three sensor types, the basic transduction mechanism does not seem to be affected by gamma radiation. The semiconductor absorption sensor shows a good radiation resistance (up to 160 kGy) in its present form, whereas the other sensor constructions need to be adapted. For the semiconductor absorption sensor, additional neutron irradiation experiments are performed, which are found to affect the principle of operation of this sensor
Keywords
fibre optic sensors; gamma-ray effects; temperature sensors; 160 kGy; Fabry-Perot cavity sensor; fluorescence sensor; gamma irradiation; neutron irradiation; nuclear environment; optical fibre temperature sensor; semiconductor absorption sensor; Degradation; Electromagnetic wave absorption; Fabry-Perot; Fluorescence; Gamma ray detectors; Gamma rays; Neutrons; Optical fibers; Sensor phenomena and characterization; Temperature sensors;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/23.685236
Filename
685236
Link To Document