Abstract :
A passive protection cell consists essentially of a t.r. cell containing argon without water vapour. The effects of the omission of water vapour from the gas filling on keep-alive characteristics, leakage power and recovery time are described. Tests on several cells in active duplexing systems have shown that lives in excess of 10000 hours are obtained.