Title :
Multiple sclerosis lesion quantification using fuzzy-connectedness principles
Author :
Udupa, J.K. ; Wei, L. ; Samarasekera, Supun ; Miki, Y. ; van Buchem, M.A. ; Grossman, R.I.
Author_Institution :
Dept. of Radiol., Pennsylvania Univ., Philadelphia, PA, USA
Abstract :
Multiple sclerosis (MS) is a disease of the white matter. Magnetic resonance imaging (MRI) is proven to be a sensitive method of monitoring the progression of this disease and of its changes due to treatment protocols. Quantification of the severity of the disease through estimation of MS lesion volume via MR imaging is vital for understanding and monitoring the disease and its treatment. This paper presents a novel methodology and a system that can be routinely used for segmenting and estimating the volume of MS lesions via dual-echo fast spin-echo MR imagery. A recently developed concept of fuzzy objects forms the basis of this methodology. An operator indicates a few points in the images by pointing to the white matter, the grey matter, and the cerebrospinal fluid (CSF). Each of these objects is then detected as a fuzzy connected set. The holes in the union of these objects correspond to potential lesion sites which are utilized to detect each potential lesion as a three-dimensional (3-D) fuzzy connected object. These objects are presented to the operator who indicates acceptance/rejection through the click of a mouse button. The number and volume of accepted lesions is then computed and output. Based on several evaluation studies, the authors conclude that the methodology is highly reliable and consistent, with a coefficient of variation (due to subjective operator actions) of 0.9% (based on 20 patient studies, three operators, and two trials) for volume and a mean false-negative volume fraction of 1.3%, with a 95% confidence interval of 0%-2.8% (based on ten patient studies).
Keywords :
biomedical NMR; fuzzy set theory; image segmentation; medical image processing; MR image analysis; cerebrospinal fluid; coefficient of variation; confidence interval; false-negative volume fraction; fuzzy connected set; fuzzy-connectedness principles; grey matter; lesion volume estimation; magnetic resonance imaging; medical diagnostic imaging; multiple sclerosis lesion quantification; subjective operator actions; Diseases; Fuzzy sets; Image segmentation; Lesions; Magnetic resonance imaging; Mice; Monitoring; Multiple sclerosis; Object detection; Protocols; Algorithms; Brain; Clinical Protocols; Computer Peripherals; Confidence Intervals; Contrast Media; Database Management Systems; Disease Progression; Evaluation Studies as Topic; False Negative Reactions; Fuzzy Logic; Gadolinium DTPA; Humans; Image Enhancement; Image Processing, Computer-Assisted; Magnetic Resonance Imaging; Multiple Sclerosis; Observer Variation; Reproducibility of Results;
Journal_Title :
Medical Imaging, IEEE Transactions on