• DocumentCode
    140003
  • Title

    Field stimulation of the carotid baroreceptor complex does not compromise baroreceptor function in spontaneously hypertensive rats

  • Author

    Kouchaki, Zahra ; Georgakopoulos, Dimitrios ; Butlin, Mark ; Avolio, Alberto P.

  • Author_Institution
    Australian Sch. of Adv. Med., Macquarie Univ., Sydney, NSW, Australia
  • fYear
    2014
  • fDate
    26-30 Aug. 2014
  • Firstpage
    2944
  • Lastpage
    2945
  • Abstract
    Field stimulation of the carotid baroreceptors has been successfully used to induce a long-term reduction in blood pressure. However, baroreceptor stimulation may interfere with or compromise the beneficial short-term blood pressure regulation function of the baroreceptors. This study aims to quantify the baroreceptor function before and during acute, unilateral field stimulation of the carotid baroreceptors. Spontaneously Hypertensive Rats (n=7) were anaesthetised and instrumented to measure heart rate and mean arterial pressure (MAP), aortic pulse wave velocity (a surrogate measure of arterial stiffness), abdominal aortic flow and renal artery flow. A custom made field stimulation device was fitted to the left common carotid artery. Baroreceptor function was measured by quantifying heart rate response to MAP change induced by bolus injection of phenylephrine. Field stimulation of the baroreceptors reduced heart rate by 20 bpm (p=0.003) with MAP reduction of 18 mmHg (p=0.008). Maximal barorecep-tor gain without stimulation was -1.20±0.41 bpm/mmHg and during stimulation -1.41±0.52 bpm/mmHg (p=0.59). The MAP at which maximal gain occurred also did not change (152±11, 160±9 mmHg respectively, p=0.22). This study indicates that unilateral field stimulation of the carotid baroreceptor complex, while causing a sustained reduction of arterial pressure, does not alter acute baroreceptor function peak gain.
  • Keywords
    biomedical equipment; blood pressure measurement; blood vessels; brain; cardiovascular system; drugs; haemodynamics; neurophysiology; MAP change; MAP reduction; abdominal aortic flow; acute baroreceptor function peak gain; anaesthetic; aortic pulse wave velocity; bolus injection; carotid artery; carotid baroreceptor complex; carotid baroreceptor function; custom made field stimulation device; heart rate measurement; heart rate response; mean arterial pressure; phenylephrine; renal artery flow; short-term blood pressure regulation function; spontaneous hypertensive rats; unilateral field stimulation; Baroreflex; Blood pressure; Carotid arteries; Heart rate; Pressure measurement; Rats; Resistance;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2014 36th Annual International Conference of the IEEE
  • Conference_Location
    Chicago, IL
  • ISSN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/EMBC.2014.6944240
  • Filename