DocumentCode
1400088
Title
Third-harmonic tuning of e.h.t. transformers
Author
Cherry, E.M.
Author_Institution
University of Melbourne, Department of Electrical Engineering, Melbourne, Australia
Volume
108
Issue
38
fYear
1961
fDate
3/1/1961 12:00:00 AM
Firstpage
227
Lastpage
236
Abstract
A detailed analysis of third-harmonic tuning of e.h.t. transformers is given, using a simple, approximate equivalent circuit. It is shown that, if the leakage inductance is tuned to about the 2.8th harmonic of the flyback pulse by the stray capacitance. (a) Ringing of the e.h.t. winding during the scan is eliminated. (b) The e.h.t. voltage pulse is maximized, the increase being 55%. (c) The voltage pulse applied to the driver tubes may be increased or decreased; the maximum possible reduction is 25%. A theoretical transformer should therefore have a pulse step-up of 1.55/0.75, i.e. 2.07 times the turns ratio; practical transformers rarely give a step-up of more than 1.5 times the turns ratio. The explanation is in the approximate nature of the equivalent circuit used for the analysis. The outline of an analysis using a complete equivalent circuit is given.
Keywords
equivalent circuits; television circuits; transformers; tuning;
fLanguage
English
Journal_Title
Proceedings of the IEE - Part B: Electronic and Communication Engineering
Publisher
iet
ISSN
0369-8890
Type
jour
DOI
10.1049/pi-b-2.1961.0039