• DocumentCode
    1401307
  • Title

    The measurement of dielectric constants in a Fabry-Perÿt resonator

  • Author

    Seeley, J.S. ; Williams, J.C.

  • Volume
    109
  • Issue
    23
  • fYear
    1962
  • fDate
    5/15/1905 12:00:00 AM
  • Firstpage
    827
  • Lastpage
    830
  • Abstract
    A resonant method for the accurate measurement of low-loss dielectric materials is described in which pieces of the material are themselves used to form the resonator. The arrangement is that of the Fabry-Perÿt interferometer, which can be used with either plane or bounded waves. The measurement involves the substitution of a half-wave piece of the material into a resonant arrangement of quarter-wave pieces. ¿r(1 ¿ j tan ¿) is evaluated from the Q-factors and the difference between the insertion losses. Any desired sensitivity can be obtained by using additional quarter-wave pieces. The method has been checked by making measurements in 3 cm waveguide on titanium-dioxide ceramic and on polystyrene. The loss tangents for both materials were found to be of the order of 0.0005 with an experimental accuracy of ±30%. Only three pieces of the titanium dioxide were required to obtain this accuracy.
  • Keywords
    dielectric properties;
  • fLanguage
    English
  • Journal_Title
    Proceedings of the IEE - Part B: Electronic and Communication Engineering
  • Publisher
    iet
  • ISSN
    0369-8890
  • Type

    jour

  • DOI
    10.1049/pi-b-2.1962.0141
  • Filename