DocumentCode
1401435
Title
An absolute method for calibrating microwave attenuators
Author
Davies, M.C.
Author_Institution
General Electric Company Limited, Central Research Laboratories, Hirst Research Centre, Wembley, UK
Volume
109
Issue
23
fYear
1962
fDate
5/15/1905 12:00:00 AM
Firstpage
796
Lastpage
800
Abstract
This method of calibrating a variable attenuator is based on the attenuation through a 3 dB coupler; an iterative process is used to take into account the absorption loss and the unequal power split of the coupler. Details are given of the procedure used for calibrating a particular attenuator, and the method of calibration at intervals of attenuation closer than the nominal 3 dB of the coupler is described. An estimate is made of the possible accuracy of the calibration, which, in the case described, was ±0.4 dB in 40 dB at a frequency of 6.2 Gc/s.
Keywords
attenuation measurement;
fLanguage
English
Journal_Title
Proceedings of the IEE - Part B: Electronic and Communication Engineering
Publisher
iet
ISSN
0369-8890
Type
jour
DOI
10.1049/pi-b-2.1962.0135
Filename
5244713