Title :
An absolute method for calibrating microwave attenuators
Author_Institution :
General Electric Company Limited, Central Research Laboratories, Hirst Research Centre, Wembley, UK
fDate :
5/15/1905 12:00:00 AM
Abstract :
This method of calibrating a variable attenuator is based on the attenuation through a 3 dB coupler; an iterative process is used to take into account the absorption loss and the unequal power split of the coupler. Details are given of the procedure used for calibrating a particular attenuator, and the method of calibration at intervals of attenuation closer than the nominal 3 dB of the coupler is described. An estimate is made of the possible accuracy of the calibration, which, in the case described, was ±0.4 dB in 40 dB at a frequency of 6.2 Gc/s.
Keywords :
attenuation measurement;
Journal_Title :
Proceedings of the IEE - Part B: Electronic and Communication Engineering
DOI :
10.1049/pi-b-2.1962.0135