• DocumentCode
    1404315
  • Title

    Fabrication and Characterization of an Integrated Microsystem for Protein Preconcentration and Sensing

  • Author

    Dextras, Philip ; Payer, Kristofor R. ; Burg, Thomas P. ; Shen, Wenjiang ; Wang, Ying-Chih ; Han, Jongyoon ; Manalis, Scott R.

  • Volume
    20
  • Issue
    1
  • fYear
    2011
  • Firstpage
    221
  • Lastpage
    230
  • Abstract
    We report on a fabrication and packaging process for a microsystem consisting of a mass-based protein detector and a fully integrated preconcentrator. Preconcentration of protein is achieved by means of a nanofluidic concentrator (NC), which takes advantage of fast nonlinear electroosmotic flow near a nanochannel-microchannel junction to concentrate charged molecules inside a volume of fluid on the order of 1 pL. Detection of preconcentrated protein samples is accomplished by passing them through a suspended microchannel resonator (SMR), which is a hollow resonant cantilever serially connected to the NC on the same device. The transit of a preconcentrated sample produces a transient shift in the cantilever´s resonance frequency that is proportional to the density of the sample and, hence, the concentration of protein contained in it. A device containing both NC and SMR structures was produced using a novel fabrication process which simultaneously satisfies the separate packaging requirements of the two structures. The initial testing of this prototype device has demonstrated that the integrated SMR can accurately measure the concentration of a bovine serum albumin solution, that was preconcentrated using the integrated NC. Future improvements in the fabrication process will allow site-specific surface modification of the device and compatibility with separation methods, which will create opportunities for its application to immunoassays and universal detection.
  • Keywords
    bioMEMS; biochemistry; biosensors; cantilevers; electronics packaging; microchannel flow; microfabrication; micromechanical resonators; molecular biophysics; nanofluidics; packaging; proteins; bovine serum albumin solution; cantilever resonance frequency; charged molecules; fabrication process; fully integrated preconcentrator; immunoassays; integrated microsystem; mass-based protein detector; microsystem; nanochannel-microchannel junction; nanofluidic concentrator; nonlinear electroosmotic flow; packaging process; protein preconcentration; prototype device; resonant cantilever; sensing; separation methods; site-specific surface modification; surface modification; suspended microchannel resonator; universal detection; Anodic bonding; glass frit bonding; ion concentration polarization; preconcentration; semiconductor device packaging; vacuum packaging; wafer scale integration;
  • fLanguage
    English
  • Journal_Title
    Microelectromechanical Systems, Journal of
  • Publisher
    ieee
  • ISSN
    1057-7157
  • Type

    jour

  • DOI
    10.1109/JMEMS.2010.2093563
  • Filename
    5668489