• DocumentCode
    1404554
  • Title

    Simple method for correction of reflection values by means of coaxial quarter wavelength air line impedance standards

  • Author

    Stumper, Ulrich

  • Volume
    27
  • Issue
    5
  • fYear
    1991
  • Firstpage
    400
  • Lastpage
    402
  • Abstract
    If only impedance standards of low quality are available for the calibration of a reflectometer of a network analyser, a simple correction method can be applied in which complex reflection coefficient values are traced to calculable air line impedance standards. The method has been tested in experiments in 14 mm and 7 mm/N coaxial techniques.
  • Keywords
    calibration; electric impedance; error correction; measurement standards; network analysers; reflectometers; air line impedance standards; coaxial techniques; complex reflection coefficient values; correction method; error box parameters; network analyser; quarter wavelength; reflection values; reflectometer calibration;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19910255
  • Filename
    64288