• DocumentCode
    1406032
  • Title

    Fabrication Error Analysis and Compensation for Guided-Mode Resonance Biosensor

  • Author

    Jia, Kehui ; Ma, Junshan

  • Author_Institution
    Shanghai Key Lab. of Contemporary Opt. Syst., Univ. of Shanghai for Sci. & Technol., Shanghai, China
  • Volume
    24
  • Issue
    4
  • fYear
    2012
  • Firstpage
    291
  • Lastpage
    293
  • Abstract
    Effects of the fabrication errors on typical double-layer guided-mode resonance filters were analyzed. The simulated results indicate that the grating period error mostly influences on the peak wavelength of biosensor. The grating period error was eliminated by adjusting the groove depth in the process of fabrication. A compensation example was given to illustrate the effectiveness of the compensations. The result shows that the peak wavelength has no deviation and the full-width at half-maximum changes slightly.
  • Keywords
    biosensors; error analysis; fabrication error analysis; full-width; grating period error; groove depth; guided-mode resonance biosensor; half-maximum; peak wavelength; typical double-layer guided-mode resonance filters; Biosensors; Fabrication; Films; Gratings; Optical filters; Optical waveguides; Optimized production technology; Biosensor; guided-mode resonance;
  • fLanguage
    English
  • Journal_Title
    Photonics Technology Letters, IEEE
  • Publisher
    ieee
  • ISSN
    1041-1135
  • Type

    jour

  • DOI
    10.1109/LPT.2011.2177520
  • Filename
    6111440