Title :
Air-Purged Electric Systems for a Large Compressor Building Having Group B Division 2 Classification
Author :
Molle, Jacques ; Shishakly, R.W. ; Fawcett, D.V.
Author_Institution :
Etudes et Recherches Industrielles SA, Brussels, Belgium
fDate :
7/1/1964 12:00:00 AM
Abstract :
To date, published material dealing with large air-purged systems1-5 has been somewhat scarce. This paper is an attempt to make more information available by presenting various arrangements for dealing with hazardous areas, explaining pressurized and purged systems, and describing a large air-purged system installation and the test results obtained during its startup.
Keywords :
Atmosphere; Fuel economy; Gases; Gears; Hazardous areas; Hydrogen; Instruments; Power generation economics; Pressure control; Societies;
Journal_Title :
Applications and Industry, IEEE Transactions on
DOI :
10.1109/TAI.1964.5407743