DocumentCode
1406403
Title
Prediction of starting performance of synchronous motor by DC decay testing method with the rotor in any arbitrary position
Author
Ara, Takahiro ; Yamamoto, Shu ; Oda, Shoichi ; Matususe, K.
Author_Institution
Dept. of Electr. Eng., Polytech.. Univ., Kanagawa, Japan
Volume
34
Issue
4
fYear
1998
Firstpage
752
Lastpage
757
Abstract
This paper presents a novel method to predict the starting performance of synchronous motors. This proposed strategy is based on a simple standstill response testing method using a small-capacity DC power supply unit, tentatively named the DC decay testing method in this paper, and can be applied to standstill synchronous motors with the rotor in any arbitrary position. The proposed testing method is carried out on a 10 kW, 200 V, 31.9 A, 50 Hz four-pole laminated salient-pole synchronous motor with damper windings. The results measured by on-load test and those predicted by the proposed method on starting performance clearly show the validity of the proposed method
Keywords
laminations; machine testing; machine theory; rotors; starting; synchronous motors; 10 kW; 200 V; 31.9 A; 50 Hz; DC decay testing method; arbitrary rotor position; damper windings; four-pole laminated salient-pole synchronous motor; small-capacity DC power supply unit; standstill response testing method; starting performance prediction; synchronous motor; Current measurement; Impedance; Industry Applications Society; Performance evaluation; Power supplies; Rotors; Synchronous machines; Synchronous motors; Testing; Voltage measurement;
fLanguage
English
Journal_Title
Industry Applications, IEEE Transactions on
Publisher
ieee
ISSN
0093-9994
Type
jour
DOI
10.1109/28.703968
Filename
703968