DocumentCode :
1406780
Title :
Feedback Compensation Using Derivative Signals I - Routh´s Criterion; Root Loci
Author :
Elliott, D.W. ; Thaler, G.J. ; Heseltine, J.C.W.
Author_Institution :
Air Anti-Submarine 41, NAS, North Island, San Diego, Calif.
Volume :
82
Issue :
68
fYear :
1963
Firstpage :
262
Lastpage :
268
Abstract :
Most signals used for feedback compensation may be treated mathematically as derivatives of the output signal. The gain associated with each derivative signal alters one or more coefficients of the characteristic equation of the closed-loop system, and may also affect the steady-state accuracy. The Routh test may be used in many simple cases to determine limiting values of the gains. In more complex cases manipulation of the characteristic equation provides a root locus assisting in design of compensation.
fLanguage :
English
Journal_Title :
Applications and Industry, IEEE Transactions on
Publisher :
ieee
ISSN :
0536-1524
Type :
jour
DOI :
10.1109/TAI.1963.5407842
Filename :
5407842
Link To Document :
بازگشت