DocumentCode
1407439
Title
Normal frequency arcover values of insulators as affected by size and humidity
Author
Frey, H. A. ; Hawley, K. A.
Author_Institution
Locke Insulator Corp., Baltimore, Md.
Volume
51
Issue
3
fYear
1932
fDate
3/1/1932 12:00:00 AM
Firstpage
192
Lastpage
192
Abstract
DATA covering the electrical characteristics of comparable insulators, as received from different sources, are frequently conflicting and a study has been made therefore to establish rules whereby such characteristics can be estimated with a reasonable degree of certainty from the dimensions of the insulators. A long series of carefully made tests are summarized in the accompanying table.
Keywords
Flashover; Humidity; Insulators; Poles and towers; Suspensions; Transient analysis;
fLanguage
English
Journal_Title
Electrical Engineering
Publisher
ieee
ISSN
0095-9197
Type
jour
DOI
10.1109/EE.1932.6429739