• DocumentCode
    1407707
  • Title

    The calibration of four-aerial adcock direction-finders

  • Author

    Ross, W.

  • Volume
    14
  • Issue
    42
  • fYear
    1939
  • fDate
    9/1/1939 12:00:00 AM
  • Firstpage
    229
  • Lastpage
    239
  • Abstract
    The paper describes how it is possible to determine the minimum radius at which a four-aerial Adcock direction-finder may be calibrated for instrumental error without introducing spurious effects due to the proximity of the calibrating transmitter to the direction-finder. It is shown that this minimum radius depends upon the spacing of the aerials, the wavelength, and the inherent accuracy of the direction-finder to be calibrated. In most cases of practical interest the minimum radius is found to be between 0.6 and 3.5 Such distances, while usually easily attainable on the short-wave band, may not be possible in the case of medium or long wavelengths.
  • fLanguage
    English
  • Journal_Title
    Wireless Section, Institution of Electrical Engineers - Proceedings of the
  • Publisher
    iet
  • Type

    jour

  • DOI
    10.1049/pws.1939.0028
  • Filename
    5245950