• DocumentCode
    1409605
  • Title

    Characteristics of Annihilation Photons Emitted From New Types of Point-Like ^{22}{\\rm Na} Radioactive Sources With Symmetric Absorber Designs

  • Author

    Hasegawa, Tomoyuki ; Sato, Yasushi ; Yamada, Takahiro ; Oda, Keiichi ; Wada, Yasuhiro ; Yoshida, Eiji ; Murayama, Hideo ; Takei, Hideyuki

  • Author_Institution
    Sch. of Allied Health Sci., Kitasato Univ., Sagamihara, Japan
  • Volume
    58
  • Issue
    1
  • fYear
    2011
  • Firstpage
    43
  • Lastpage
    50
  • Abstract
    Purpose: Point-like 22Na radioactive sources have been widely used for checking radiation detectors that measure annihilation photons and for evaluating PET scanners. We developed new types of 22Na point-like radioactive sources that are expected to be more symmetric than conventional source types in the angular distribution of the emitted photons. The purpose of this study is to use Monte Carlo simulation to investigate the basic characteristics of the photons emitted from the new type 22Na point-like radioactive sources. Methods: Two new types of 22Na point-like sources, a cylinder type and a sphere type, were considered in comparison with two conventional source types, a disk type and a cube type. The angular distribution and energy spectra of the emitted 0.511 MeV annihilation photons and 1.275 MeV gamma rays were calculated using a Monte Carlo code based on Geant4. Results: The angular distribution of the emitted photons was more symmetric in the new type point-like sources than in the conventional types. The asymmetry of the angular distribution of the unscattered 0.511 MeV annihilation photon pairs counted in coincidence was 0.1 ±0.1% and 1.6±0.1% in the sphere and cylinder types, compared with 4.1±0.1% and 22.6±0.1% for the cube and disk types. The scatter components around the 0.511 MeV photopeaks in the new source types were typically less than 2/3 and 1/2 of those in the disk and cube types, respectively. Conclusion: The new point-like 22Na sources offer a more symmetric angular distribution of the emitted photons with fewer scatter components. They are useful for applications where the symmetry of the emitted photons is crucial.
  • Keywords
    calibration; positron emission tomography; radioactive sources; 22Na; Monte Carlo code; Monte Carlo simulation; PET scanners; annihilation photons; cube type; cylinder type; disk type; energy spectra; point-Like 22Na radioactive sources; positron emission tomography; radiation detectors; sphere type; symmetric absorber designs; symmetric angular distribution; Calibration; positron emission tomography;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2010.2090898
  • Filename
    5672816