DocumentCode :
141014
Title :
Mechanical heart valve cavitation in patients with bileaflet valves
Author :
Johansen, Peter ; Andersen, Tina S. ; Hasenkam, J. Michael ; Nygaard, Hans ; Paulsen, Peter K.
Author_Institution :
Dept. of Eng., Univ. of Aarhus, Aarhus, Denmark
fYear :
2014
fDate :
26-30 Aug. 2014
Firstpage :
5655
Lastpage :
5658
Abstract :
Today, the quality of mechanical heart valves is quite high, and implantation has become a routine clinical procedure with a low operative mortality (<; 5%). However, patients still face the risks of blood cell damage, thromboembolic events, and material failure of the prosthetic device. One mechanism found to be a possible contributor to these adverse effects is cavitation. In vitro, cavitation has been directly demonstrated by visualization and indirectly in vivo by registering of high frequency pressure fluctuations (HFPF). Tilting disc valves are thought of having higher cavitation potential than bileaflet valves due to higher closing velocities. However, the thromboembolic potential seems to be the same. Further studies are therefore needed to investigate the cavitation potential of bileaflet valves in vivo. The post processing of HFPF have shown difficulties when applied on bileaflet vavles due to asynchronous closure of the two leaflets. The aim of this study was therefore to isolate the pressure signature from each leaflet closure and perform cavitation analyses on each component. Six patients were included in the study (St. Jude Medical (n=3) and CarboMedics (n=3); all aortic bileaflet mechanical heart valves). HFPFs were recorded intraoperatively through a hydrophone at the aortic root. The pressure signature relating to the first and second leaflet closure was isolated and cavitation parameters were calculated (RMS after 50 kHz highpass filtering and signal energy). Data were averaged over 30 heart cycles. For all patients both the RMS value and signal energy of the second leaflet closure were higher than for the first leaflet closure. This indicates that the second leaflet closure is most prone to cause cavitation. Therefore, quantifying cavitation based on the HFPF related to the second leaflet closure may suggest that the cavitation potential for bileaflet valves in vivo may be higher than previous studies have suggested.
Keywords :
artificial organs; blood; cellular biophysics; hydrophones; aortic root; bileaflet valves; blood cell damage; high frequency pressure fluctuations; hydrophone; material failure; mechanical heart valve cavitation; operative mortality; prosthetic device; thromboembolic events; tilting disc valves; Educational institutions; Filtering; Heart; In vivo; Prosthetics; Sonar equipment; Valves;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society (EMBC), 2014 36th Annual International Conference of the IEEE
Conference_Location :
Chicago, IL
ISSN :
1557-170X
Type :
conf
DOI :
10.1109/EMBC.2014.6944910
Filename :
6944910
Link To Document :
بازگشت