DocumentCode
1410160
Title
Low-inductance 100 kV switch (spark gap) for starting, diverting and clamping capacitor discharges
Author
Bishop, A.E. ; Edmonds, G.D.
Author_Institution
UKAEA, Cuiham Laboratory, Abingdon, UK
Volume
113
Issue
9
fYear
1966
fDate
9/1/1966 12:00:00 AM
Firstpage
1549
Lastpage
1556
Abstract
The development of an accurately triggered, pressurised spark gap of the field-distortion type operating in the cascade mode up to 100kV is described. The effects of variations in the air pressure and in the magnitude and polarity of the charging and trigger voltages have been determined. Designed initially as a switch for starting a high-frequency capacitor discharge (250kc/s), it has also been adapted for diverting and clamping such discharges at currents up to 200kA, passing up to 20C per discharge.
Keywords
capacitors; discharges (electric); switches;
fLanguage
English
Journal_Title
Electrical Engineers, Proceedings of the Institution of
Publisher
iet
ISSN
0020-3270
Type
jour
DOI
10.1049/piee.1966.0263