• DocumentCode
    14118
  • Title

    FlexiSPECT: A SPECT System Consisting of a Compact High-Resolution Scintillation Detector (SPECTatress) and a Lofthole Collimator

  • Author

    Deprez, Karel ; Vandenberghe, Stefaan ; Vandeghinste, Bert ; Van Holen, Roel

  • Author_Institution
    Med. Image & Signal Process. Group, Ghent Univ., Ghent, Belgium
  • Volume
    60
  • Issue
    1
  • fYear
    2013
  • fDate
    Feb. 2013
  • Firstpage
    53
  • Lastpage
    64
  • Abstract
    This article describes a compact single-photon emission computed tomography (SPECT) system that consists of a high-resolution detector combined with a lofthole collimator. The detector is based on a NaI(Tl) scintillator, a position sensitive photomultiplier (PSPMT), dedicated read-out electronics that digitize all PSPMT anodes and finally, a maximum likelihood algorithm for position estimation. The collimator has a new pinhole geometry, called the lofthole. Our choice of magnification (1.06 for the mouse setup, 0.63 for the rat setup) results in a small system with a footprint of 45 cm × 25 cm. Design and measurements of both the detector and the SPECT system are shown. Detector measurements with a beam source have been done to investigate the spatial and energy resolution of the detector. Two SPECT setups have been made, one that fits rat-size phantoms and one that fits mouse-size phantoms. On both setups we have done measurements of a Derenzo phantom and a uniformity phantom. The results show that the detector resolution is 1.1 mm and energy resolution is 9.3% in the center of the detector. With the tomographic rat setup we are able to distinguish the 2.4 mm hot rods in a Derenzo phantom. The mouse setup allows us to distinguish the 1.6 mm rods. This demonstrates the SPECT capabilities of this compact prototype scanner.
  • Keywords
    collimators; geometry; maximum likelihood estimation; photomultipliers; position sensitive particle detectors; readout electronics; scintillation counters; single photon emission computed tomography; sodium compounds; Derenzo phantom; FlexiSPECT; NaI(Tl) scintillator detector; PSPMT anodes; SPECT system; SPECTatress; compact high-resolution scintillation detector; compact prototype scanner; lofthole collimator; maximum likelihood algorithm; mouse-size phantoms; pinhole geometry; position estimation; position sensitive photomultiplier; rat-size phantoms; read-out electronics; uniformity phantom; Apertures; Collimators; Detectors; Maximum likelihood estimation; Phantoms; Sensitivity; Single photon emission computed tomography; MLE; MLEM; NaI(Tl); PSPMT; SPECT; pinhole;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2012.2236575
  • Filename
    6413252