• DocumentCode
    1411960
  • Title

    Measurement of beam-loaded resonant frequency and quality factor in a gyroklystron input cavity using noise emissions

  • Author

    Calame, J.P. ; Garven, M. ; Danly, Bruce G.

  • Author_Institution
    Naval Res. Lab., Washington, DC, USA
  • Volume
    28
  • Issue
    3
  • fYear
    2000
  • fDate
    6/1/2000 12:00:00 AM
  • Firstpage
    638
  • Lastpage
    644
  • Abstract
    The spectral shape of noise emissions from a 35-GHz gyroklystron input cavity is used to directly measure the cavity resonant frequency and quality factor under beam-loaded conditions. The quality factors obtained with this technique at a number of magnetic fields are found to be consistent with quality factors obtained from reflection coefficient measurements made at the identical operating points. The measured variation in quality factor is used to identify various regimes of operation based on input cavity coupling. Comparisons between the measurements and simulations are in good agreement in resonant frequency, but moderate discrepancies in quality factor exist
  • Keywords
    Q-factor; digital simulation; gyrotrons; klystrons; 35 GHz; beam-loaded conditions; beam-loaded resonant frequency; cavity resonant frequency; gyroklystron input cavity; input cavity coupling; magnetic fields; noise emissions; operating points; quality factor measurement; quality factors; reflection coefficient measurements; spectral shape; Frequency measurement; Klystrons; Magnetic field measurement; Magnetic noise; Noise measurement; Noise shaping; Q factor; Resonant frequency; Shape measurement; Spectral shape;
  • fLanguage
    English
  • Journal_Title
    Plasma Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-3813
  • Type

    jour

  • DOI
    10.1109/27.887691
  • Filename
    887691