Introduction - Human electrical safety standards are based almost exclusively on animal studies and there is an unjustified assumption that ventricular fibrillation (VF) thresholds in animals are the same as those in humans. Methods and Results - We analyzed differences between animals and humans in cardiac stimulation. A broad literature survey revealed that swine are a fragile electrophysiologic research species and have a dense intramural Purkinje fiber network, which is not found in some other species, including humans. Anesthesia agents have to be chosen carefully as swine are prone to malignant hyperthermia. Cardiac stimulation thresholds depend on weight and capture rates. Thus, the animal weight has to be representative of the weight of human subjects. Studies have shown significant ECG differences between humans and other species, including swine and canine. At least one study suggested that rabbit hearts tend to develop VF in a manner more similar to that seen in humans. Conclusion - Animal studies can play a role in conservatively evaluating cardiac safety. However, while still abiding by the precautionary principle, animal study design has to take into account the significant anatomical and electrophysiological differences between humans and other mammals. Data from multiple animal models may offer broader perspectives. If attempts are made to extrapolate animal results to humans then appropriate numerical correction factors should be applied, such as some of those discussed in this article.
Keywords :
bioelectric phenomena; biological effects of fields; electrocardiography; physiological models; ECG differences; VF; anatomical differences; anesthesia agents; animal electrical cardiac safety models; animal study design; animal weight; canine; capture rates; cardiac stimulation thresholds; dense intramural Purkinje fiber network; electrophysiologic research species; electrophysiological differences; human electrical safety standards; human subject weight; malignant hyperthermia; mammals; multiple animal models; numerical correction factors; precautionary principle; rabbit hearts; swine; ventricular fibrillation thresholds; Animals; Electrical safety; Fibrillation; Heart; Myocardium; Optical fiber networks; Safety;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society (EMBC), 2014 36th Annual International Conference of the IEEE
Conference_Location :
Chicago, IL
ISSN :
1557-170X
Type :
conf
DOI :
10.1109/EMBC.2014.6945113
Filename :
6945113
Link To Document :
بازگشت