• DocumentCode
    1413397
  • Title

    Electrical testing of rubber covered wire

  • Author

    Protzman, C. W. ; Hill, W. M.

  • Author_Institution
    Western Elec Co., Inc., Baltimore, Md.
  • Volume
    52
  • Issue
    6
  • fYear
    1933
  • fDate
    6/1/1933 12:00:00 AM
  • Firstpage
    409
  • Lastpage
    412
  • Abstract
    An improved method for providing electrical breakdown tests of rubber covered wire has been developed which for telephone wire presents many advantages. The previously used water test has been replaced by a dry test, and one machine combines the testing and coiling operations. Details of the method are presented in this article.
  • Keywords
    Coils; Electrodes; Insulation; Relays; Sparks; Testing; Wires;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineering
  • Publisher
    ieee
  • ISSN
    0095-9197
  • Type

    jour

  • DOI
    10.1109/EE.1933.6430760
  • Filename
    6430760