• DocumentCode
    1413696
  • Title

    Determining the Optimal Window Length for Pattern Recognition-Based Myoelectric Control: Balancing the Competing Effects of Classification Error and Controller Delay

  • Author

    Smith, Lauren H. ; Hargrove, Levi J. ; Lock, Blair A. ; Kuiken, Todd A.

  • Author_Institution
    Feinberg Sch. of Med., Northwestern Univ., Chicago, IL, USA
  • Volume
    19
  • Issue
    2
  • fYear
    2011
  • fDate
    4/1/2011 12:00:00 AM
  • Firstpage
    186
  • Lastpage
    192
  • Abstract
    Pattern recognition-based control of myoelectric prostheses has shown great promise in research environments, but has not been optimized for use in a clinical setting. To explore the relationship between classification error, controller delay, and real-time controllability, 13 able-bodied subjects were trained to operate a virtual upper-limb prosthesis using pattern recognition of electromyogram (EMG) signals. Classification error and controller delay were varied by training different classifiers with a variety of analysis window lengths ranging from 50 to 550 ms and either two or four EMG input channels. Offline analysis showed that classification error decreased with longer window lengths ( p <; 0.01). Real-time controllability was evaluated with the target achievement control (TAC) test, which prompted users to maneuver the virtual prosthesis into various target postures. The results indicated that user performance improved with lower classification error (p <; 0.01 ) and was reduced with longer controller delay ( p <; 0.01), as determined by the window length. Therefore, both of these effects should be considered when choosing a window length; it may be beneficial to increase the window length if this results in a reduced classification error, despite the corresponding increase in controller delay. For the system employed in this study, the optimal window length was found to be between 150 and 250 ms , which is within acceptable controller delays for conventional multistate amplitude controllers.
  • Keywords
    electromyography; medical signal processing; neurophysiology; pattern classification; prosthetics; real-time systems; EMG; classification error; competing effects; controller delay; conventional multistate amplitude controllers; electromyogram signals; myoelectric control; myoelectric prosthesis; optimal window length; pattern recognition; target achievement control testing; virtual upper-limb prosthesis; Classification algorithms; Controllability; Delay; Electromyography; Pattern recognition; Prosthetics; Real time systems; Controller delay; myoelectric control; pattern recognition; prosthesis; surface electromyography; Algorithms; Artificial Limbs; Computer Simulation; Data Interpretation, Statistical; Electrodes; Electromyography; Electrophysiological Phenomena; Humans; Linear Models; Muscle, Skeletal; Pattern Recognition, Visual; Prosthesis Design; Software; User-Computer Interface;
  • fLanguage
    English
  • Journal_Title
    Neural Systems and Rehabilitation Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1534-4320
  • Type

    jour

  • DOI
    10.1109/TNSRE.2010.2100828
  • Filename
    5676233