• DocumentCode
    1413756
  • Title

    Amplitude and asymmetry correlation study between quasistatic and dynamic electrical testing of MR sensors

  • Author

    Zhu, Jun ; Loera, Moises

  • Author_Institution
    Phase Metrics Inc., San Diego, CA, USA
  • Volume
    34
  • Issue
    4
  • fYear
    1998
  • fDate
    7/1/1998 12:00:00 AM
  • Firstpage
    1525
  • Lastpage
    1527
  • Abstract
    The peak amplitudes of a shielded MR sensor are shown to be well correlated over a wide range of hard-axis magnetic fields and bias currents between quasi-static and dynamic electrical testing. The peak asymmetry correlation appears to be head design specific. Write disturbances significantly increase the standard deviation of the amplitude and asymmetry repeatability measurements. The presence of a small dc easy-axis magnetic field has little effect on MR responses to uniform fields
  • Keywords
    correlation methods; magnetic heads; magnetic sensors; magnetoresistive devices; testing; asymmetry correlation; bias currents; dynamic electrical testing; hard-axis magnetic fields; head design; peak amplitude; quasistatic electrical testing; shielded magnetoresistive sensor; write disturbances; Current measurement; Magnetic field measurement; Magnetic heads; Magnetic recording; Magnetic sensors; Magnetic shielding; Permanent magnets; Pulse measurements; Testing; Time measurement;