Abstract :
Experience recorded in this paper with the method of measuring the radio influence factor of electrical apparatus recommended by the Joint Co-ordination Committee on Radio Reception of Edison Electric Institute, National Electrical Manufacturers Association, and Radio Manufacturers Association establishes its practicability and adequacy. This method fulfills the essential feature of all working standards in that the results are reproducible by quantitative measurements.